Quando ocorre falha de contato em um conector em uma linha coaxial de transmissão de sinal HF, um campo eletromagnético é irradiado ao redor da linha. Medimos o campo eletromagnético e examinamos as características dessa radiação. Os resultados mostram que a radiação está relacionada com a resistência de contato e com a simetria da distribuição dos pontos de contato no conector. Quando a resistência de contato é baixa, a radiação é observada em frequências ressonantes relacionadas ao comprimento da linha de transmissão. Se um conector tiver pontos de contato axialmente assimétricos, sua radiação será maior do que quando os pontos de contato forem simétricos. Mostramos que se os pontos de contato em um conector forem axialmente simétricos com resistência inferior a 0.25 Ω, a interferência eletromagnética causada pela falha no contato do conector é tão baixa quanto o ruído de fundo.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copiar
Yu-ichi HAYASHI, Hideaki SONE, "Fundamental Measurement of Electromagnetic Field Radiated from a Coaxial Transmission Line Caused by Connector Contact Failure" in IEICE TRANSACTIONS on Electronics,
vol. E91-C, no. 8, pp. 1306-1312, August 2008, doi: 10.1093/ietele/e91-c.8.1306.
Abstract: When contact failure occurs in a connector in a coaxial HF signal transmission line, an electromagnetic field is radiated around the line. We have measured the electromagnetic field and examined the characteristics of such radiation. The results show that the radiation is related to the contact resistance and the symmetry of the distribution of contact points at the connector. When contact resistance is low, radiation is observed at resonant frequencies related to the length of the transmission line. If a connector has axially asymmetric contact points, its radiation is higher than that when the contact points are symmetric. We show that if contact points in a connector are axially symmetrical with resistance lower than 0.25 Ω, the electromagnetic interference caused by the connector contact failure is as low as the background noise.
URL: https://global.ieice.org/en_transactions/electronics/10.1093/ietele/e91-c.8.1306/_p
Copiar
@ARTICLE{e91-c_8_1306,
author={Yu-ichi HAYASHI, Hideaki SONE, },
journal={IEICE TRANSACTIONS on Electronics},
title={Fundamental Measurement of Electromagnetic Field Radiated from a Coaxial Transmission Line Caused by Connector Contact Failure},
year={2008},
volume={E91-C},
number={8},
pages={1306-1312},
abstract={When contact failure occurs in a connector in a coaxial HF signal transmission line, an electromagnetic field is radiated around the line. We have measured the electromagnetic field and examined the characteristics of such radiation. The results show that the radiation is related to the contact resistance and the symmetry of the distribution of contact points at the connector. When contact resistance is low, radiation is observed at resonant frequencies related to the length of the transmission line. If a connector has axially asymmetric contact points, its radiation is higher than that when the contact points are symmetric. We show that if contact points in a connector are axially symmetrical with resistance lower than 0.25 Ω, the electromagnetic interference caused by the connector contact failure is as low as the background noise.},
keywords={},
doi={10.1093/ietele/e91-c.8.1306},
ISSN={1745-1353},
month={August},}
Copiar
TY - JOUR
TI - Fundamental Measurement of Electromagnetic Field Radiated from a Coaxial Transmission Line Caused by Connector Contact Failure
T2 - IEICE TRANSACTIONS on Electronics
SP - 1306
EP - 1312
AU - Yu-ichi HAYASHI
AU - Hideaki SONE
PY - 2008
DO - 10.1093/ietele/e91-c.8.1306
JO - IEICE TRANSACTIONS on Electronics
SN - 1745-1353
VL - E91-C
IS - 8
JA - IEICE TRANSACTIONS on Electronics
Y1 - August 2008
AB - When contact failure occurs in a connector in a coaxial HF signal transmission line, an electromagnetic field is radiated around the line. We have measured the electromagnetic field and examined the characteristics of such radiation. The results show that the radiation is related to the contact resistance and the symmetry of the distribution of contact points at the connector. When contact resistance is low, radiation is observed at resonant frequencies related to the length of the transmission line. If a connector has axially asymmetric contact points, its radiation is higher than that when the contact points are symmetric. We show that if contact points in a connector are axially symmetrical with resistance lower than 0.25 Ω, the electromagnetic interference caused by the connector contact failure is as low as the background noise.